Product Detail

N3013 FLASH STOP Powder Water Sealant

3013 FLASH STOP
Powder Water Sealant

It is a polymer reinforced powder insulation material that contains special type cement and chemical additives, used in insulation and repair of active water leaks, hardens within 2-3 minutes when reacting with water and provides high adherence.

Consumption
First layer consumption: 1,50 kg/m2 mixture
Second layer consumption: 1,30 kg/m2 mixture
Package
Component A: In 20 kg kraft bags.
Component B: In 10 It plastic jerrycans.
N3013 Flash Stop
Quality Certificates:
Manufactured according to TS EN 1504-3 / R2

Whatsapp

Places of Usage
• Indoors-outdoors, vertical and horizontal applications,
• For repairing new static (stationary) cracks,
• For isolation of active water leaks,
• Waterproofing of pipe and cable passages,
• For repairing defects in concrete,
• Filling and blocking water leaks before insulation,
• In filling tie-rod iron cavities,
• For chamfering of concrete edge and corner joints and cold joint repairs.

Features/ Advantages
• It is single component, mixed with water only.
• It stops active water leaks by sudden setting.
• Easy to use.
• Expands to form a waterproof sealant.
• Has high strength and stability.
• After 15 minutes, insulation materials can be applied on.
• Does not cause corrosion of steel reinforcement as it does not contain chlorine.
• Safely used in drinking water tanks.

Application Directions
a) Surface Preparation:
The application surface should be solid, dry, carrier, dust-free and clean. The surface should be cleaned from all kinds of oil, grease, rust, tar, paint and curing materials that will reduce adherence. Existing cracks and gaps should be cut with 20mm depth and width with vertical edges. V-shaped gaps should be avoided, sharp corner details should not be left.
b) Product Preparation:
After N3013 Flash Stop is poured into a clean application container in the amount you can consume in 60 seconds and enough water is added, mix by hand using a suitable glove. Do not mix for more than 30 seconds.

ATTENTION: Use warm or hot water in cold weather. Do not add aggregates, chemicals or foreign substances to the mixture.
c)Application Method:
Repair of Active Water Leaks; Open the crack with active water leakage until it reaches a solid ground with a width and depth of at least 20 mm. Mix N3013 Flash Stop with appropriate amount of water, become conical shape in your hand and then when it starts to heat up, apply it to the area of active water leakage with a single movement. Apply pressure by holding your hand steady for at least 45 seconds. After the material has hardened, remove your hand slowly. Repeat the above procedure several times from the circumference of the gap to the center for repair of gaps that cannot be closed at once. Immediately after application, remove any excess material around the cavity with suitable equipment. To Insulate Wall-Floor Cold Joint in an Existing Structure; The cold joint must be opened with a width and depth of at least 20 mm or until it reaches solid ground. Wire, wooden wedges or similar materials should be removed from the surface. Then, the
opening joint must be filled with N3013 Flash Stop appropriately.
To Fix Metal Anchors or Fasteners to Reinforced Concrete;
On the reinforced concrete surface, the anchoring cavity should be opened with suitable mechanical drilling tools and more space than the diameter of the anchoring element. Then all dust and weak materials in the cavity should be removed. The anchoring cavity should be saturated with water before application. The prepared anchoring cavities should be filled with enough N3013 Flash Stop. The anchoring element should be quickly turned and placed in the direction of its vertical axis and ensured that N3013 Flash Stop dull.

Issues to be Considered
• For 3013 Flash Stop application, If the ambient and surface temperature is below +5° C or above +25° C, appropriate temperatures should be waited.
N3013 Flash Stop gets fast setting as a result of rising hydration temperature. It should therefore be kept moist for 15 minutes. This should be 30 minutes on dry and absorbent surfaces.
• The operating and reaction times of systems containing special cements are influenced by ambient and ground temperature and relative humidity in the air. The reaction slows down at low temperatures, which increases the pot life and working time. High temperatures accelerate the reaction and the above-mentioned times shorten accordingly.
• In order for the material to cure, the ambient and ground temperature must not fall below the minimum permissible temperature.
• In cold weather applications, to maximize the workability of the material, the packages should be conditioned at + 20° C to + 25° C and ready for use.

Cleaning of Tools:
Tools and equipment used should be cleaned with water after the application. N3013 Flash Stop can only be removed mechanically from the surface after hardening.

Security Warnings
• S2 Keep out of the reach of children.
• S24/25 Avoid contact with eyes and skin.
• S26 In contact with eye, wash with water and consult a doctor.
• S28 In contact with skin, wash immediately with plenty of water.
• S29 Do not empty into drains.
• S46 If swallowed, consult a doctor immediatelySand show box or label.

Consumption
First layer consumption: 1,50 kg/m2 mixture
Second layer consumption: 1,30 kg/m2 mixture

Package
Component A: In 20 kg kraft bags.
Component B: In 10 It plastic jerrycans.
N3013 Flash Stop
Quality Certificates:
Manufactured according to T5 EN 1504-3 / R2

Export to the Middle East and Europe

Production with Special Production Techniques

Recipes for All Needs

Full Time Secure Shipping

Copyrights © 2024 Neroflex