Product Detail

N1017 BLOCKER Gas Concrete Adhesive

N1017 BLOCKER
Gas Concrete Adhesive

It is cement based, water and frost resistant, fiber added, gas concrete mortar with high performance, single component, high stability, that can be used outdoors, horizontal and vertical surfaces.

Consumption: Average 4-5 kg/m2
Package: In 25 kg kraft bags. 

N1017 Blocker
Quality Certificates:
Manufactured according to TS EN 12004.

Whatsapp

Places of Usage:
• For bonding gas concrete brick,
• For bonding pressed brick,
• For bonding pumice brick

Features/ Advantages:
• It has high adhesion strength.
• Easy to comb.
• Saves time and labor.

Application Directions:
a) Surface Preparation:
Before application, gas concrete, pumice and pressed brick blocks should be checked and if there are wet, they should be allowed to dry. The gas concrete blocks are cut to the desired size with a gas concrete saw before the wall is built. In highly porous surfaces and hot air applications (if the surface temperature is above +25°C), the surface must be pre-wetted in a way to be moistened for the appropriate temperature. Thus,
it will prevent the adhesive from losing its water quickly.
b) Product Preparation:
1 Bag (25 kg) N1017 Blocker is added slowly into 6-6,5 kg water and mixed for 5 minutes with 400-600 rpm mixer until it reaches a paste consistency. The prepared mixture is allowed to rest for 5 minutes, then mixed again and applied to the surface with an appropriate trowel. Proper chiseling is performed. For the smoothness of the wall surface, thesmoothness of the horizontal and vertical joints can be ensured by using a rubber hammer, especially the first row should be very smooth. After the material is applied to the surface with a trowel and combed, it must be adhered according to the air temperature and the climatic conditions where the material is used. In such cases, the adhesive surface is pressed with finger and the adhesive surface is checked. If the material gets on the fingers, the bonding process is continued. Otherwise, the bonding process should be terminated and the dried adhesive material should be scraped off the surface and the new adhesive applied to the surface. All tools and equipment used should be cleaned with water before the mortar dries after application. The manufacturer's instructions on the packaging must be observed before and during the application. Inspect Neroflex Mill-Mixed Plaster to apply plaster to gas concrete, pumice block or hollow brick surfaces.
c)Application Method:
The prepared mortar is spread on the surface with a notched trowel or trowel with appropriate tooth size. The prepared mortar should be adhered on the gas concrete within 5 minutes. If this time has elapsed, the mortar should be scraped off the surface and the coatings. The laid bricks should be rammed from the top and side and made suitable to the rope and template. The amount of consumption given is theoretical and may vary depending on the application temperature, gas concrete brick size, surface and labor. We recommend sample application for consumption control.

Issues to be Considered:
• Since the water absorption of the gas concrete blocks is high, the adhesive mortar should not be left open for a long time after being applied on the gas concrete. Otherwise, the adhesive surface dries and does not provide good adhesion.
• In order to get better efficiency from the gas concrete adhesive, it is necessary to sweep the dust and particles on the block and the application should be done so that the horizontal and vertical surfaces of the gas concrete block are completely
covered with adhesive mortar.
• Do not use wedges between the wall and the beam during the application.
• Gas concrete is the masonry wall material with the lowest thermal conductivity. There is no contribution of the adhesive material to the thermal conductivity.
• Application under sun and strong wind should be avoided. Application should be done when the surface temperature is between +5° C and +25° C.
• Protective gloves are recommended for applications. For more detailed protective measures, please obtain the material safety data sheet from the manufacturer.

Cleaning of Tools:
Tools and equipment used should be cleaned with water after the application. N1017 Blocker can only be removed mechanically from the surface after hardening.

Security Warnings:
• S2 Keep out of the reach of children.
• S24/25 Avoid contact with eyes and skin.
• S26 In contact with eye, wash with water and consult a doctor.
• S28 In contact with skin, wash immediately with plenty of water.
• S29 Do not empty into drains.
• S46 If swallowed, consult a doctor immediatelyand show box or label.

Storage:
It should be stored in unopened original package in a cool and dry environment by protecting from frost. For short-term storage, maximum 3 pallets should be placed over and over and the shipment should be made with first in first out system. For
long-term storage, pallets should not be placed over and over. It can be stored for 12 months from the date of production if proper storage conditions are met. Opened packages should be kept tightly closed and stored under proper storage conditions and should be used within one week.

Consumption: Average 4-5 kg/m2
Package: In 25 kg kraft bags. 


N1017 Blocker
Quality Certificates:
Manufactured according to TS EN 12004.

Export to the Middle East and Europe

Production with Special Production Techniques

Recipes for All Needs

Full Time Secure Shipping

Copyrights © 2024 Neroflex